Calculation and Analysis of Balanced Loads in 20 kV Distribution System (Feeder 8) in Gleno Distribution Transformer
Abstract
This study focuses on the calculation and analysis of balanced loads in the 20 kV distribution system, specifically Feeder 8 in the Gleno Distribution Transformer, East Timor. The research aims to address the issue of load imbalance, which leads to voltage drops and power losses in the distribution network. Data were collected from eight transformers in the Gleno area, and simulations were conducted using ETAP 12.6 to analyze voltage, current, and power losses. The results indicate significant imbalances in load distribution, particularly during peak hours, resulting in neutral currents and energy losses. Recommendations are provided to improve load balancing and enhance the efficiency of the distribution system.
Downloads
References
Santos, J. R., & Pereira, L. F. (2021). Real-time monitoring of unbalanced loads in rural distribution grids: A Timor Leste case. International Journal of Electrical Power & Energy Systems, 133, 107291. https://doi.org/10.1016/j.ijepes.2021.107291
Khan, B., & Singh, P. (2020). Smart grid and renewable energy systems: Modeling and simulation. Wiley IEEE Press.
IEEE Std. 1547-2018 (Revised 2022). IEEE standard for interconnection and interoperability of distributed energy resources with associated electric power systems interfaces. IEEE.
Gomez Exposito, A., et al. (2021). Electric energy systems: Analysis and operation (3rd ed.). CRC Press.
Rahman, M. A., et al. (2022). Neutral current reduction in LV distribution networks using dynamic load balancing. IEEE Transactions on Power Delivery, 37(4), 3205-3214. https://doi.org/10.1109/TPWRD.2022.3151183
Zhang, X., & Chen, H. (2023). Transformer aging and failure due to unbalanced loads: Diagnostics and solutions. Springer.
UNDP Timor Leste. (2023). Renewable energy integration in Timor-Leste’s grid: Challenges and opportunities. Policy report.
IEEE PES Task Force. (2020). Best practices for mitigating voltage imbalance in distribution systems. IEEE.
ETAP 16.0 White Paper. (2024). Advanced load flow analysis for unbalanced distribution networks. ETAP.
IEC 60076-7:2018 – Guidelines for transformer loadability under unbalanced conditions.
EDTL Grid Code (2021) – National regulations for 20 kV distribution system operation (internal document).
Copyright (c) 2025 Quintão Fátima dos Santos, Jaime Godinho Soares, Rumbidzai Lorraine Siband